Availability: | |
---|---|
Quantity: | |
GS6.6
Beautylife
Human body elements analyzer machine GS6.6
Body composition analyzer work theory:
Human body elements analysis equipment, applies the accurate measurement of AVR micro computer controller, bases on new statistics method DXA, analysis human elements: fat weight BMI(body mass index), non-fat and other health indicators through multi-frequency bioelectrical impedance analysis melthod(MFBIA). give instruction on guests' health. and provide a scientific basis for losing weight effectively. Which is considered as an epoch-making results of the health industry. If is health consultants, and it provide an independent analysis of health data for each test. Applicable to major fitness, body centers, medical centers, senior clubs, supporting projects of losing weight.
Machine introduction:
Specification:
Test Method | Multi-frequency bioelectrical impedance analysis (MFBIA) |
Test Part | bioelectrical impedance analysis on the part of left upper limb, right upper limb, trunk, left lower extremity, right lower extremity |
Test Frequency | Three differenct frequency(20KHZ, 50KHZ, 100KHZ) |
Electrode Method | 8 point contact eletrode |
Computing method of body components | Do not estimate through empirical value |
Output Value(25) | TBW, protein, mineral salt, Body fat, bone weight, Weight,IBW, fat-free weight, SMM(Skeletal muscle), BMI(Body mass index), PDF(percentage of body fat), WHP(waist-hip ratio),moisture ratio, Obesity diagnosis, nutritional assessment, Weight assessment, obesity assessment, Goal weight,Weight control,Fat control, Muscle control, Health assessment, basic metabolism, bioelectrical impedance. |
Rated current | less than 180μA |
Power | Input power: AC100~240V, 50/60HZ |
Screen | 320*240 STN LCD Touching Screen |
Operation Language | English and Multiple Language Option |
Values Storage | 50000×10 and SD Card unlimited expansion is available |
External Storage | SD Card tranfer to computer for large storage |
External Interfaces | RJ-45, USB2 |
Printer Interfaces | USB |
IC Card System | standard IC card control |
Printer | A4 color paper ink-jet printer(manufacturers appoint the model), internally installed thermal printer |
MEAS. Of Package | 49CM*50CM*118CM, GW: 40KG; NW:32KG. MEAS. Of printer package: 63CM*44CM*38CM |
Test time | No more than 2 minutes |
Operation Environment | Temperature: 10~400°C(50~1040°F),humidity: 30~80%RH, 500~600hPa |
Conservation Environment | Temperature: 0~400°C(32~1040°F),humidity: 30~80%RH, 500~600hPa |
Test scope of weight | 10~200Kg; Test scope of age: 10~99 ages; Test scope of height: 90~200cm |
External expansion project | Ultrasonic Height Measurer(selective purchasing) |
Human body elements analyzer machine GS6.6
Body composition analyzer work theory:
Human body elements analysis equipment, applies the accurate measurement of AVR micro computer controller, bases on new statistics method DXA, analysis human elements: fat weight BMI(body mass index), non-fat and other health indicators through multi-frequency bioelectrical impedance analysis melthod(MFBIA). give instruction on guests' health. and provide a scientific basis for losing weight effectively. Which is considered as an epoch-making results of the health industry. If is health consultants, and it provide an independent analysis of health data for each test. Applicable to major fitness, body centers, medical centers, senior clubs, supporting projects of losing weight.
Machine introduction:
Specification:
Test Method | Multi-frequency bioelectrical impedance analysis (MFBIA) |
Test Part | bioelectrical impedance analysis on the part of left upper limb, right upper limb, trunk, left lower extremity, right lower extremity |
Test Frequency | Three differenct frequency(20KHZ, 50KHZ, 100KHZ) |
Electrode Method | 8 point contact eletrode |
Computing method of body components | Do not estimate through empirical value |
Output Value(25) | TBW, protein, mineral salt, Body fat, bone weight, Weight,IBW, fat-free weight, SMM(Skeletal muscle), BMI(Body mass index), PDF(percentage of body fat), WHP(waist-hip ratio),moisture ratio, Obesity diagnosis, nutritional assessment, Weight assessment, obesity assessment, Goal weight,Weight control,Fat control, Muscle control, Health assessment, basic metabolism, bioelectrical impedance. |
Rated current | less than 180μA |
Power | Input power: AC100~240V, 50/60HZ |
Screen | 320*240 STN LCD Touching Screen |
Operation Language | English and Multiple Language Option |
Values Storage | 50000×10 and SD Card unlimited expansion is available |
External Storage | SD Card tranfer to computer for large storage |
External Interfaces | RJ-45, USB2 |
Printer Interfaces | USB |
IC Card System | standard IC card control |
Printer | A4 color paper ink-jet printer(manufacturers appoint the model), internally installed thermal printer |
MEAS. Of Package | 49CM*50CM*118CM, GW: 40KG; NW:32KG. MEAS. Of printer package: 63CM*44CM*38CM |
Test time | No more than 2 minutes |
Operation Environment | Temperature: 10~400°C(50~1040°F),humidity: 30~80%RH, 500~600hPa |
Conservation Environment | Temperature: 0~400°C(32~1040°F),humidity: 30~80%RH, 500~600hPa |
Test scope of weight | 10~200Kg; Test scope of age: 10~99 ages; Test scope of height: 90~200cm |
External expansion project | Ultrasonic Height Measurer(selective purchasing) |